Slow Damped Oscillatory Wave Simulator SWCS-900 Series Conforming to IEC60255-22-1
GENERAL
This Simulator unit is compliant with Damped Oscillatory Wave Immunity Test required by IEC60255-22-1 1 MHz burst immunity tests for measuring relays and protecting equipment. Also, it is capable to execute the other 100KHz Slow Damped Oscillatory Wave immunity test defined in IEC61000-4-18 2006 ed1.0.
FEATURES
Capable of generating two slow damped oscillatory waveforms compliant with IEC61000-4-18(2006)
Maximum Output Voltage of 3kV allows flexible tests
Touch-panel which provides superior setting visibility
Selectable coupling modes by internal switches
Coupling onto signal or other lines by connecting the output port to optional external CDN
Built-in Power Line CDN (AC240V/DC125V 20A)
Combinable with high capacity CDN (optional)
SPECIFICATIONS
Parameters Specifications
Surge waveform Slow Damped Oscillatory Wave
Output voltage 0.20kV~3.0kV ±10% (10V step)
Short-circuit current 1.25A~15A ±20%
Oscillation frequency 100kHz 1MHz
Repetition Frequency 40Hz 400Hz
Envelop decay time 50% of the 1st peak 20µs ~ 45µs 20µs ~ 45µs
Rise time Rise time of the first peak 75ns±20%
Output impedance 200 ohm ±10%
Polarity Positive and negative of the first peak
Test duration
TIMER mode: fixed at 2s
CONTINUE mode: operator starts and stops the test
CDN power capacity Single phase / three phase : AC240V 20A DC125V 20A
Coupling modes
Normal mode: between L1/L2/L3/N
Common mode: L1/L2/L3/N to PE
Decoupling coil 1.5mH
Decoupling capacitor 0.5µF
Operating power supply / Power consumption C100V~240V ±10% 50/60Hz
Weight Approx. 20kgs (Except accessories)
Dimensions (W)430 x (H)350 x (D)470mm (Projection excluded)
WAVEFORM IMAGE
T1: Rise time (75s)
T: Repetition period (10µs or 1µs)
*The above waveform is referential only.